Wattage60W
InputG: 9~36Vdc, L: 18~72Vdc, H: 40~160Vdc
Output(VDC)3.3,5,12,24
PFC-
SafetyEAC CE
L*W*H128*60*25mm
Warranty3 Years
  • Description
  • Product review

60W Reliable Railway DC-DC Converter RSD-60 series

  • Compliance to EN50155 and EN45545-2 railway standard

  • UItra compact and 1U low profile(25mm)

  • 4: 1 wide input range

  • No minimum load required

  • Protections: Short circuit/Overload/ Over voltage/Input reverse polarity

  • 4000VDC I/O isolation(reinforced isolation)

  • Half encapsulated, cooling by free air convection

  • -40-+70 C wide working temperature

  • Built-in constant current limiting circuit

  • LED indicator for power on

  • 3 years warranty

specification:

ORDER NO. RSD-60G-3.3 RSD-60G-5 RSD-60G-12 RSD-60G-24 RSD-60G-3.3 RSD-60G-5 RSD-60G-12 RSD-60G-24
OUTPUT DC VOLTAGE 3.3V 5V 12V 24V 3.3V 5V 12V 24V
RATED CURRENT 12A 12A 5A 2.5A 12A 12A 5A 2.5A
CURRENT RANGE 0 ~ 12A 0 ~ 12A 0 ~ 5A 0 ~ 2.5A 0 ~ 12A 0 ~ 12A 0 ~ 5A 0 ~ 2.5A
RATED POWER 39.6W 60W 60W 60W 39.6W 60W 60W 60W
RIPPLE & NOISE (max.) Note.2 60mVp-p 100mVp-p 50mVp-p 50mVp-p 60mVp-p 60mVp-p 50mVp-p 50mVp-p
VOLTAGE TOLERANCE Note.3 ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0%
LINE REGULATION ±0.5% ±0.5% ±0.3% ±0.2% ±0.5% ±0.5% ±0.3% ±0.2%
LOAD REGULATION ±0.5% ±0.5% ±0.3% ±0.2% ±0.5% ±0.5% ±0.3% ±0.2%
SETUP, RISE TIME 100ms, 60ms at full load
HOLD UP TIME (Typ.) G type comply with S1 level(3ms) full load,S2 level(10ms) @50% load S2 10 @ ; Ltype comply with level(10ms) @full load
INPUT VOLTAGE RANGE 9 ~ 36VDC 18 ~ 72VDC
EFFICIENCY(Typ.) 86.5% 88%92% 90% 88.5% 89% 93% 91.5%
EFFICIENCY(Typ.) 2.1A/24VDC 3A/24VDC 0.95A/48VDC 1.5A/48VDC
DC CURRENT(Typ.) 20A/24VDC 20A/48VDC