Item specifics
- Wattage
- 65w
- Input
- 85-264VAC
- Output(Vdc)
- 5v 12v -5v,5v 12v -12v,5v 15v -15v,5v 24v 12v
- PFC
- -
- Safety
- UL,TUV,CB,CE,EMC
- L*W*H
- 129*98*38mm (L*W*H)
- Warranty
- 3 years
Review
Description
65W Triple Output Switching Power Supply RT-65 series
Feature:
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105 long life electrolytic capacitors°C
Withstand 300VAC surge input for 5 second
High operating temperature up to 70°C
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
specification:
MODEL RT-65A RT-65B RT-65C RT-65D OUTPUT OUTPUT NUMBER CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3 DC VOLTAGE 5V 12V -5V 5V 12V -12V 5V 15V -15V 5V 24V 12V RATED CURRENT 6A 2.8A 0.5A 5A 2.8A 0.5A 5A 2.2A 0.5A 4A 1.5A 1A CURRENT RANGE 0.5 ~ 8A 0.2 ~ 3.5A 0.1 ~ 1A 0.5 ~ 8A 0.2 ~ 3.5A 0.1 ~ 1A 0.5 ~ 8A 0.2 ~ 3A 0.1 ~ 1A 0.5 ~ 8A 0.2 ~ 2A 0.1 ~ 1A RATED POWER 66.1W 64.6W 65.5W 68W RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 80mVp-p 80mVp-p 120mVp-p 80mVp-p 80mVp-p 120mVp-p 80mVp-p 80mVp-p 150mVp-p 120mVp-p VOLTAGEADJ. RANGE CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 ±2.0% ±6.0% ±5.0% ±2.0% ±6.0% ±5.0% ±2.0% ±8.-4% ±5.0% ±2.0% ±4.-6% ±6.0% LINE REGULATION Note.4 ±0.5% ±1.5% ±0.5% ±0.5% ±1.5% ±0.5% ±0.5% ±1.5% ±0.5% ±0.5% ±1.5% ±2.0% LOAD REGULATION Note.5 ±1.0% ±3.0% ±1.0% ±1.0% ±3.0% ±1.0% ±1.0% ±3.0% ±1.0% ±1.0% ±3..0% ±4.0% SETUP, RISE TIME 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load HOLD UP TIME (Typ.) 60ms/230VAC14ms/115VAC at full load INPUT VOLTAGE RANGE 88 ~ 264VAC125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 77% 77% 78% 79% AC CURRENT (Typ.) 2A/115VAC 1.2A/230VAC0.55A/230VAC INRUSH CURRENT (Typ.) COLD START 40A/230VAC LEAKAGE CURRENT <2mA/ 240VAC
65W Triple Output Switching Power Supply RT-65 series
Feature:
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105 long life electrolytic capacitors°C
Withstand 300VAC surge input for 5 second
High operating temperature up to 70°C
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
specification:
MODEL | RT-65A | RT-65B | RT-65C | RT-65D | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
OUTPUT | OUTPUT NUMBER | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 |
DC VOLTAGE | 5V | 12V | -5V | 5V | 12V | -12V | 5V | 15V | -15V | 5V | 24V | 12V | |
RATED CURRENT | 6A | 2.8A | 0.5A | 5A | 2.8A | 0.5A | 5A | 2.2A | 0.5A | 4A | 1.5A | 1A | |
CURRENT RANGE | 0.5 ~ 8A | 0.2 ~ 3.5A | 0.1 ~ 1A | 0.5 ~ 8A | 0.2 ~ 3.5A | 0.1 ~ 1A | 0.5 ~ 8A | 0.2 ~ 3A | 0.1 ~ 1A | 0.5 ~ 8A | 0.2 ~ 2A | 0.1 ~ 1A | |
RATED POWER | 66.1W | 64.6W | 65.5W | 68W | |||||||||
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 80mVp-p | 80mVp-p | 120mVp-p | 80mVp-p | 80mVp-p | 120mVp-p | 80mVp-p | 80mVp-p | 150mVp-p | 120mVp-p | |
VOLTAGEADJ. RANGE | CH1: 4.75 ~ 5.5V | CH1: 4.75 ~ 5.5V | CH1: 4.75 ~ 5.5V | CH1: 4.75 ~ 5.5V | |||||||||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±6.0% | ±5.0% | ±2.0% | ±6.0% | ±5.0% | ±2.0% | ±8.-4% | ±5.0% | ±2.0% | ±4.-6% | ±6.0% | |
LINE REGULATION Note.4 | ±0.5% | ±1.5% | ±0.5% | ±0.5% | ±1.5% | ±0.5% | ±0.5% | ±1.5% | ±0.5% | ±0.5% | ±1.5% | ±2.0% | |
LOAD REGULATION Note.5 | ±1.0% | ±3.0% | ±1.0% | ±1.0% | ±3.0% | ±1.0% | ±1.0% | ±3.0% | ±1.0% | ±1.0% | ±3..0% | ±4.0% | |
SETUP, RISE TIME | 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load | ||||||||||||
HOLD UP TIME (Typ.) | 60ms/230VAC14ms/115VAC at full load | ||||||||||||
INPUT | VOLTAGE RANGE | 88 ~ 264VAC125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) | |||||||||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||||||||
EFFICIENCY (Typ.) | 77% | 77% | 78% | 79% | |||||||||
AC CURRENT (Typ.) | 2A/115VAC 1.2A/230VAC0.55A/230VAC | ||||||||||||
INRUSH CURRENT (Typ.) | COLD START 40A/230VAC | ||||||||||||
LEAKAGE CURRENT | <2mA/ 240VAC |