- Wattage
- 150w
- Input
- 85-264VAC
- Output(Vdc)
- 3.3, 5, 12, 15, 24, 48
- PFC
- -
- Safety
- CUL,TUV,CCC,CB,CE,BSMI,EAC
- L*W*H
- 199*98*38mm (L*W*H)
- Warranty
- 3 years
Product review
Description
150W Single Output Switching Power Supply RS-150 series
Feature:
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105°Clong life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70°C
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
specification:
MODEL | RS-150-3.3 | RS-150-5 | RS-150-12 | RS-150-15 | RS-150-24 | RS-150-48 | |
---|---|---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 3.3V | 5V | 12V | 15V | 24V | 48V |
RATED CURRENT | 30A | 26A | 12.5A | 10A | 6.5A | 3.3A | |
CURRENT RANGE | 0 ~ 30A | 0 ~ 26A | 0 ~ 12.5A | 0 ~ 10A | 0 ~ 6.5A | 0 ~ 3.3A | |
RATED POWER | 99W | 130W | 150W | 150W | 156W | 158.4W | |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 80mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 3.2 ~ 3.5V | 4.75 ~ 5.5V | 11.4 ~ 13.2V | 14.25 ~ 16.5V | 22.8 ~ 26.4V | 45.6 ~ 52.8V | |
VOLTAGE TOLERANCE Note.3 | ±3.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION Note.4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION Note.5 | ±2.0% | ±1% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 800ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load | ||||||
HOLD UP TIME (Typ.) | 28ms/230VAC 20ms/115VAC at full load | ||||||
INPUT | VOLTAGE RANGE | 88 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 373VDC(Withstand 300VAC surge for 5sec. Without damage) | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||
EFFICIENCY (Typ.) | 74% | 78% | 83% | 84% | 86% | 87% | |
AC CURRENT (Typ.) | 3A/115VAC 2A/230VAC | ||||||
INRUSH CURRENT (Typ.) | COLD START 40A/230VAC | ||||||
LEAKAGE CURRENT | <2mA / 240VAC |