Description
100W Single Output Switching Power Supply RS-100 series
Feature:
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105°Clong life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70°C
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
specification:
MODEL RS-100-3.3 RS-100-5 RS-100-12 RS-100-15 RS-100-24 RS-100-48 OUTPUT DC VOLTAGE 3.3V 5V 12V 15V 24V 48V RATED CURRENT 20A 16A 8.5A 7A 4.5A 2.3A CURRENT RANGE 0 ~ 20A 0 ~ 16A 0 ~ 8.5A 0 ~ 7A 0 ~ 4.5A 0 ~ 2.3A RATED POWER 66W 80W 102W 105W 108W 110.4W RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 120mVp-p 120mVp-p 120mVp-p 200mVp-p VOLTAGE ADJ. RANGE 3.2 ~ 3.5V 4.75 ~ 5.5V 11.4 ~ 13.2V 14.25 ~ 16.5V 22.8 ~ 26.4V 45.6 ~ 52.8V VOLTAGE TOLERANCE Note.3 ±3.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% LINE REGULATION Note.4 ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% LOAD REGULATION Note.5 ±2.0% ±1% ±0.5% ±0.5% ±0.5% ±0.5% SETUP, RISE TIME 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load HOLD UP TIME (Typ.) 100ms/230VAC 18ms/115VAC at full load INPUT VOLTAGE RANGE 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 74% 77% 81% 82% 84% 84% AC CURRENT (Typ.) 2.5A/115VAC 1.5A/230VAC INRUSH CURRENT (Typ.) COLD START 40A/230VAC LEAKAGE CURRENT <2mA / 240VAC
100W Single Output Switching Power Supply RS-100 series
Feature:
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105°Clong life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70°C
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
specification:
MODEL | RS-100-3.3 | RS-100-5 | RS-100-12 | RS-100-15 | RS-100-24 | RS-100-48 | |
---|---|---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 3.3V | 5V | 12V | 15V | 24V | 48V |
RATED CURRENT | 20A | 16A | 8.5A | 7A | 4.5A | 2.3A | |
CURRENT RANGE | 0 ~ 20A | 0 ~ 16A | 0 ~ 8.5A | 0 ~ 7A | 0 ~ 4.5A | 0 ~ 2.3A | |
RATED POWER | 66W | 80W | 102W | 105W | 108W | 110.4W | |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 80mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 3.2 ~ 3.5V | 4.75 ~ 5.5V | 11.4 ~ 13.2V | 14.25 ~ 16.5V | 22.8 ~ 26.4V | 45.6 ~ 52.8V | |
VOLTAGE TOLERANCE Note.3 | ±3.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION Note.4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION Note.5 | ±2.0% | ±1% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load | ||||||
HOLD UP TIME (Typ.) | 100ms/230VAC 18ms/115VAC at full load | ||||||
INPUT | VOLTAGE RANGE | 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||
EFFICIENCY (Typ.) | 74% | 77% | 81% | 82% | 84% | 84% | |
AC CURRENT (Typ.) | 2.5A/115VAC 1.5A/230VAC | ||||||
INRUSH CURRENT (Typ.) | COLD START 40A/230VAC | ||||||
LEAKAGE CURRENT | <2mA / 240VAC |